As a factory, we offer the UP-3014 Cantilever Beam (IZOD) Impact Tester for precise and reliable testing. Ensure quality and efficiency with our equipment.
A. High-precision intelligent controller equipped with LCD display which you can read the data intuitively and accurately; B. China's first carbon fiber lever (It has been patented); it succeeds in doing experiments without shaking involving the impact direction, improving the rigidity of materials, and concentrating impacting strength on the centroid of the pendulum, and using life increases. C. Imported high-resolution digital encoders, higher and more stable angle measurement accuracy; D. Aerodynamic impact hammer and imported ball bearings greatly reduce mechanical friction losses E.Automatic calculation of the final result, 12 sets of the test data can be stored and averaged; F. Optional interface of Chinese and English; units ( J / m, KJ / m2, kg-cm / cm, ft-ib / in )can be customized according to customers’ requirements. G. Built-in mini printer to print the test data
Item
Charpy Impact
Izod Impact
Pendulum energy
1J, 2J, 4J, 5J
1J, 2.75J, 5.5J
Pendulum angle
150°
Blade angle
30°
Blade front angle
5°
Blade back angle
10°
Impact speed
2.9m/s
3.5m/s
Impact center distance
221mm
335mm
Blade filleted radius
R=2mm±0.5mm
R=0.8mm±0.2mm
Energy loss
0.5J ≤4.0J
1.0J ≤2.0J
2.0J ≤1.0J
≥4.0J≤0.5J
2.75J ≤0.06J
5.5J ≤0.12J
Pendulum torque
Pd1J=0.53590Nm
Pd2J=1.07180Nm Pd4J=2.14359Nm Pd5J=2.67949Nm
Pd2.75J=1.47372Nm
Pd5.5J=2.94744Nm
Print out
Capacity. Angle, energy, etc.
Power supply
AC220V±10% 50HZ
ISO179—2000 Determination of Plastics - Hard Materials Charpy Impact Strength GB/T1043—2008 Rigid Plastic Charpy Impact Test Method JB/T8762—1998 Plastics Charpy Impact Testing Machine GB/T 18743-2002 Charpy Impact Test Method for Fluid Transport Via Thermoplastic Pipe (Suitable for pipe pieces)